isibhengezo_sekhasi

imikhiqizo

ABB CI853K01 3BSE018103R1 Dual RS232-C Interface

incazelo emfushane:

Inombolo yomthetho: CI853K01 3BSE018103R1

Igama lomkhiqizo: ABB

Isikhathi sokulethwa: Esitokweni

Inkokhelo: T/T

imbobo yemikhumbi: xiamen

intengo: $1200


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Incazelo

Ukukhiqiza I-ABB
Imodeli I-CI853K01
Ulwazi loku-oda Idatha ye-3BSE018103R1
Ikhathalogi 800xA
Incazelo I-CI853K01 Dual RS232-C Interface
Umsuka I-Sweden (SE)
Ikhodi ye-HS 85389091
Ubukhulu 16cm*16cm*12cm
Isisindo 0.8kg

Imininingwane

CI853 RS-232 module amaphrothokholi:

I-COMLI ingasetshenziswa ekwakheni echwebeni le-COM3 futhi ngokuzikhethela kumachweba we-CI853.Ubude bekhebula bunganwetshwa kakhulu (kumakhilomitha ambalwa) kusetshenziswa isiguquli se-fiber optic.I-RS-232C iyindlela yokuxhumana ejwayelekile esetshenziselwa ukuxhumana kwe-serial ne-COMLI.I-CI853 isekela Ukushintshwa Okushisayo.I-COMLI iyiphrothokholi ye-ABB yokudluliswa kwedatha phakathi kwabalawuli.Yakhelwe ukuxhumana kwe-asynchronous master/slave in half-duplex.Iphrothokholi ye-COMLI isekela imodemu yokudayela elawulwa kuhlelo lokusebenza.I-CI853 isekela kokubili imodi ye-Master/Slave ku-COMLI.

I-MODBUS RTU iyiphrothokholi ejwayelekile esatshalaliswa kabanzi ngenxa yokusebenziseka kwayo kalula nokuthembeka.I-Modbus RTU iyiphrothokholi evulekile, ye-serial (RS-232 noma RS-485) etholakala ku-Master/Slave architecture ishintshisana ngolwazi ngemodi eyi-duplex ewuhhafu.Ukusebenza kwe-Modbus kungalungiselelwa kokubili kumachweba we-COM we-AC 800M kanye ne-CI853.I-Module Redundancy ayitholakali ku-MODBUS RTU.I-CI853 isekela kuphela i-Master mode ku-MODBUS RTU.

 

Izici nezinzuzo

  • I-COMLI ingasetshenziswa ekwakheni echwebeni le-COM3 futhi ngokuzikhethela kumachweba we-CI853.I-RS-232C iyindlela yokuxhumana ejwayelekile esetshenziselwa ukuxhumana kwe-serial ne-COMLI.I-CI853 isekela Ukushintshwa Okushisayo.I-COMLI iyiphrothokholi ye-ABB yokudluliswa kwedatha phakathi kwabalawuli.
  • I-MODBUS RTU iyiphrothokholi evulekile, ye-serial (RS-232 noma RS-485) ethathwe ku-Master/Slave architecture ishintshisana ngolwazi ngemodi eyi-duplex ewuhhafu.Ukusebenza kwe-Modbus kungalungiselelwa kokubili kumachweba we-COM we-AC 800M kanye ne-CI853.
  • I-Siemens 3964R ingasetshenziswa ekwakhiweni kwembobo ye-COM3 futhi ngokuzikhethela kumachweba we-CI853.Kudingeka isiteshi sokuxhumana esijwayelekile i-RS-232C/485.
  • Ukuzichaza Kwe-Serial Communication kungasetshenziswa embotsheni eyakhelwe ku-COM3 (ku-AC 800M Controller) futhi ngokuzikhethela kumachweba we-CI853.
  • Imojula ye-CI853 iphinde isekele Ukushintshwa Okushisayo.

  • Okwedlule:
  • Olandelayo:

  • Thumela umlayezo wakho kithi: