isibhengezo_sekhasi

imikhiqizo

I-Honeywell 80366481-175 Ibhodi Lesifunda Le-Analog Output

incazelo emfushane:

Inombolo yomthetho: 80366481-175

uphawu: Honeywell

intengo: $800

Isikhathi sokulethwa: Esitokweni

Inkokhelo: T/T

ichweba lokuthumela: xiamen


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Incazelo

Ukukhiqiza I-Honeywell
Imodeli 80366481-175
Ulwazi loku-oda 80366481-175
Ikhathalogi TDC2000
Incazelo I-Honeywell 80366481-175 Ibhodi Lesifunda Le-Analog Output
Umsuka USA
Ikhodi ye-HS 3595861133822
Ubukhulu 3.2cm*10.7cm*13cm
Isisindo 0.3kg

Imininingwane

I-Nonincendive FTAs (imikhawulo yamanje) Amanye ama-Field Termination Assemblies (FTAs) asetshenziswa ohlelweni olungaphansi Lwesiphathi Senqubo Yokusebenza Okuphezulu anabameleli kumasekhethi okukhiphayo ukuze akhawulele okwamanje okutholakala kumatheminali enkundla. Lawa masekethi okukhiphayo ahloliwe futhi aqinisekiswa yi-Factory Mutual njengawe-Nonincendive. Lokhu kusho ukuthi uma izintambo zenkambu zivulwa ngephutha, zifushanisiwe, noma zisekelwe phansi futhi i-HPM isebenza ngokujwayelekile, izintambo ngeke zikhiphe amandla anele ukuze zibangele ukuthungela emkhathini oshiwo ovuthayo. Ithebula 5-3 liwuhlu lokokufaka kwe-analog, okukhiphayo kwe-analog, nama-FTA okufakwayo edijithali anomphumela we-Nonincendive. Futhi, lapho amasekhethi aphumayo edijithali we-FTA ephumayo yedijithali engawamanje futhi amandla kagesi akhawulelwe kumazinga afanelekile ngumsebenzisi, i-FTA ephumayo yedijithali nayo ingabhekwa njenge-Nonincendive. Amapharamitha ekhebula nokulayisha (amapharamitha ebhizinisi) Ukuqinisekisa ukuthi izifunda zenkundla azikwazi ukuthungela umhwamuko othile ovuthayo, ubukhulu bekhebula nemingcele yomthwalo kufanele kwaziwe futhi kulawulwe. Ithebula 5-3 linikeza amanani aphezulu avunyelwe amapharamitha we-FTA ngayinye esohlwini lwethebula. Ukugunyazwa kwekhodi kagesi Ngokuvamile, izintambo zensimu endaweni eyingozi yoPhiko 2 kufanele zenziwe ngokuya ngamakhodi endawo; Nokho, kwezinye izindawo, izintambo ze-Nonincendive akudingeki zihambisane nemithetho evamile ye-Division 2 yezintambo, kodwa zingasebenzisa izindlela zokufaka izintambo ezifanele izindawo ezijwayelekile. Bheka i-ANSI/ISA S12.12, ingxenye ethi “Izisetshenziswa zikagesi ezizosetshenziswa Ekilasini I, Isigaba 2 Sezindawo Eziyingozi [Ezihlukaniswe].” Inani lamanje le-resistor elikhawulelayo Inani lezinto eziphikisayo kuma-FTA asohlwini likhethiwe ukuze kuqinisekiswe ama-currents amasekethe amafushane kakhulu endaweni eyingozi engaphansi kwama-milliamp angu-150 kumpahla yokusebenza evamile. Ngokuya kokushicilelwe kwe-NFPA #493, I-Intrinsically Safe Apparatus for Use in Division 1 Izindawo Eziyingozi, ama-milliamp angu-150 asuka kumthombo we-Vdc angu-24 angaphansi komkhawulo wokuthungela kuyisekethi ephikisayo yamagesi kuzindawo zamaQembu A ukuya ku-D.

80360206-001(1)

80360206-001(2)

80366481-175


  • Okwedlule:
  • Olandelayo:

  • Thumela umlayezo wakho kithi: